HEB

Europe · EN 10365 (IPE / HE)

HEB sections are European wide-flange H-sections with flange width roughly equal to depth, the standard (heavier) HE series. Thicker flanges and webs give high capacity and balanced stiffness, making HEB a common choice for columns and heavily loaded members.

At the same nominal size HEB carries more load than the lighter HEA; where the design is governed by capacity rather than weight, HEB is the usual default of the two.

Reading the size: An HEB is named by nominal depth in millimetres: "HEB300" is around 300 mm in nominal size. Mass per metre is fixed for each size by the standard.

Properties are indicative - verify against the governing standard before professional use.

HEB sizes (15)

Designation Profile Mass
kg/m
Depth
mm
Width
mm
tw
mm
tf
mm
Area
mm²
Ix
mm⁴
Zx
mm³
Sx
mm³
HEB100
20.4 100 100 6 10 2,604 4,495,000 89,910 104,200
HEB120
26.7 120 120 6.5 11 3,401 8,644,000 144,100 165,200
HEB140
33.7 140 140 7 12 4,296 15,090,000 215,600 245,400
HEB160
42.6 160 160 8 13 5,425 24,920,000 311,500 354,000
HEB180
51.2 180 180 8.5 14 6,525 38,310,000 425,700 481,400
HEB200
61.3 200 200 9 15 7,808 56,960,000 569,600 642,500
HEB220
71.5 220 220 9.5 16 9,104 80,910,000 735,500 827,000
HEB240
83.2 240 240 10 17 10,599 112,600,000 938,300 1,053,000
HEB260
93 260 260 10 17.5 11,844 149,200,000 1,148,000 1,283,000
HEB280
103.1 280 280 10.5 18 13,136 192,700,000 1,376,000 1,534,000
HEB300
117 300 300 11 19 14,908 251,700,000 1,678,000 1,869,000
HEB320
126.7 320 300 11.5 20.5 16,134 308,200,000 1,926,000 2,149,000
HEB340
134.2 340 300 12 21.5 17,090 366,600,000 2,156,000 2,408,000
HEB360
141.8 360 300 12.5 22.5 18,063 431,900,000 2,400,000 2,683,000
HEB400
155.3 400 300 13.5 24 19,778 576,800,000 2,884,000 3,232,000

tw web thickness · tf flange thickness · Ix second moment of area · Zx elastic / Sx plastic section modulus, major axis. Open any size for the full table, an SI / imperial toggle and a scaled cross-section.

Frequently asked

What is an HEB section?
HEB is a European (EN 10365) wide-flange H-section with width about equal to depth, the standard HE series. Its thick flanges and web suit columns and high-capacity members.
When should I use HEB instead of HEA?
Use HEB when capacity governs: at the same nominal size it has thicker flanges and web than HEA, so more strength and stiffness, at the cost of extra weight.
How do I read an HEB size?
The number is the nominal size in millimetres: HEB300 is the 300 series. Each size has a fixed mass per metre defined by EN 10365.
Design with HEB in CivilKit Beams →