310UC118

Universal Columns · AS/NZS 3679.1 (designed to AS 4100)

The 310UC118 is a 315 mm deep, 307 mm wide universal column with a mass of 118 kg/m, listed for Australia / New Zealand (AS/NZS 3679.1 (designed to AS 4100)).

Indicative properties - verify against the governing standard before professional use.

D 315 b 307 tw 11.9 tf 18.7
310UC118 cross-section (mm, to scale). Download DXF
Mass per metre 118 kg/m
Depth 315 mm
Flange width 307 mm
Web thickness 11.9 mm
Flange thickness 18.7 mm
Area 15,000 mm²
Second moment of area, Iₓ 277,000,000 mm⁴
Elastic modulus, Zₓ 1,760,000 mm³
Plastic modulus, Sₓ 1,950,000 mm³
Analyse a 310UC118 beam in CivilKit Beams →

Free in your browser. No install, no sign-up.

Frequently asked

How much does a 310UC118 weigh?
A 310UC118 has a mass of 118 kg/m (79.3 lb/ft).
What are the dimensions of a 310UC118?
A 310UC118 is 315 mm deep and 307 mm wide, with a 11.9 mm web and a 18.7 mm flange.
What is the section modulus of a 310UC118?
Its elastic section modulus Zₓ is 1,760,000 mm³ and its plastic section modulus Sₓ is 1,950,000 mm³, about the major (x-x) axis.